ME3830B

$434.00

In addition to all the features of the ME3030B:

  • It comprises the full frequency response required by the standard of building biology: 16 Hz to 100 kHz. And it is - unique in this price range - fully compensated up to 100 kHz for bias-free results.

  • This means that the ARTIFICIAL harmonics ("Dirty Power") are also registered, e.g. from LED and fluorescent lamps, from switching power supplies and from the electronic devices, even those of dimmers or consumer electronics, all of which are almost omnipresent in today’s households and in offices.

Quantity:
Add To Cart

In addition to all the features of the ME3030B:

  • It comprises the full frequency response required by the standard of building biology: 16 Hz to 100 kHz. And it is - unique in this price range - fully compensated up to 100 kHz for bias-free results.

  • This means that the ARTIFICIAL harmonics ("Dirty Power") are also registered, e.g. from LED and fluorescent lamps, from switching power supplies and from the electronic devices, even those of dimmers or consumer electronics, all of which are almost omnipresent in today’s households and in offices.

In addition to all the features of the ME3030B:

  • It comprises the full frequency response required by the standard of building biology: 16 Hz to 100 kHz. And it is - unique in this price range - fully compensated up to 100 kHz for bias-free results.

  • This means that the ARTIFICIAL harmonics ("Dirty Power") are also registered, e.g. from LED and fluorescent lamps, from switching power supplies and from the electronic devices, even those of dimmers or consumer electronics, all of which are almost omnipresent in today’s households and in offices.

Needless to say that the device fulfills all the other advantages of the series:

  • The reading shows the total pollution directly in the entity corresponding to the building biology standard values - without any calculation required.

  • It measures magnetic AND electric fields based on scientifically accepted measuring methods and with high sensitivity (display resolution: 1 nT or 1 V / m).

  • The "Geiger counter effect" helps to identify areas of increased LF stress.

  • The included detailed measurement instruction enables the user to perform relevant measurements of EMF – even without technical expertise. With the help of this instrument you can spot - even obscured - sources of LF pollution.

  • Also the manual includes the recommendations for limiting values according to the standard of building biology SBM, which allow for a meaningful assessment of the personal level of EMF pollution.

  • Many patents have been granted to us, the devices have tenthousandfold proven their reliability, and have shown to be leading-edge in their price categories.

SPECIFICATIONS

Item weight:0,40 kg

Frequency range: 16 Hz - 100 KHz (compensated, better than -2 dB)

Scope of delivery:

Measuring device
Grounding cable
Alkaline manganese battery
Detailed instruction manual with neutral background information

Measurement range:

Magnetic flux density (one-dimensional): 1 - 1999 nT
Electric field strength: 1 - 1999 V/m

Precision: +/- 2 %, +/- 14 digits @ 50/60 Hz

Sensor:

E-field sensor for electric LF alternating fields
H-field sensor for magnetic LF alternating fields (one-dimensional)

Audio analysis:

Sound signal proportional to field strength (with "Geiger counter effect", switchable)

Signal rating: RMS

Power supply:

9-volt E-block alkaline manganese battery (included), average operating time: 24 to 36 hours (depending on operating mode)
Low-Batt. indicator
Auto power-off function

Garantie: 2 years